April 03, 2020
Background
ETSI published European Standard ETSI EN 300 220-2 v3.2.1 (2018-06) on March 31, 2019.
Applicable States & Regions
European Union countries and regions
Important Dates
Date of Publish: March 31, 2019
Date of Withdraw: March 31, 2020
Product Scope
The present document specifies technical characteristics and methods of measurements for Non-specific Short-range Devices category equipment types. For example: 433 MHz remote control, 868 MHz alarm, etc.
Significant Changes
- Clause 3
- Add two definitions in clause 3.1: Nomadic use & Portable use
- Clause 4
- Change the description of the applicability for PSD in clause 4.3.2.0: Deleting annex B bands L, and changing annex C band X to band W, AA & AC
- Change the description of the applicability for ACP in clause 4.3.9.0: Changing annex C band AA to band AF
- Change the description of the applicability for FHSS equipment in clause 4.3.10.0: Adding the operating frequency range 863 MHz to 870 MHz
- Change the limit for blocking in clause 4.4.2.2: Deleting the category 3 receiver
- Annex B
- Change the requirement for band D in Table B.1: Adding 10% for metering devices duty cycle limit
- Change the requirement for band E, G & M in Table B.1: Deleting the application of the equipment
- Change the requirement for band L in Table B.1: Deleting the requirement of PSD
- Delete the requirement for band O in Table B.1
- Annex C
- Delete the requirement for 169.475-169.600 MHz in Table C.1
- Add the requirement for band U, V, W, X and AB in Table C.1
- Add the requirement of APC for band AA in Table C.1
- Change the OBW requirement from the whole band to 7 MHz for band Z in Table C.1
SGS Services
With our worldwide laboratory network and rich certification experience, SGS can provide enterprises with comprehensive testing and certification solutions, greatly reduce the cost and cycle-time, and help enterprises quickly enter their target market(s).
For more information, please contact our Customer Service Team!