Helium Leak Test


Helium Leak Test

Principle

This test is performed by introducing helium gas into the internal space of the test material and over-pressurizing. The helium gas will flow through any welding seam flaws, cracks or pin holes. Any leaking helium gas will be sucked into a sniper which has been attached to a helium mass spectrometer. The gas will be ionized in the ion chamber by an electronic beam generated by a filament. A helium ion collector gathers only helium ions and will send an amplified signal to the indicator. The leakage can be measured by the signal strength.

Application

  • LNG Carrier
  • LNG Terminal
  • High-pressurizing pipe line
  • Overall industries

Equipment

  • Cabin (Vacuum pump, Compressor, Flow-meter, Multi-display, Recorder, Mercury mano meter, Water manometer, Stopwatch, Radio. Etc.)
  • Dried air supply
  • Helium manifold
  • Temperature sensor
  • Transportation robot including multi sniffers
  • Helium mass spectrometer
  • Reference leak
  • Global box
Transportation robot
Potable sniffer

Procedure

Please click here to see the Procedure

Evaluation

  • A re-examination will have to be performed should the devices malfunction or the correct test procedure are not followed.
    The re-examination shall be accepted should the result be under the stipulated leakage value.