Email this pageEmail this pagePrint this pagePrint this page
Share on LinkedInShare on LinkedInShare on FacebookShare on FacebookTweet thisTweet this

Mining

Categories

Minimize menuMaximize menu

Minimize menuMaximize menuHomeMiningSite Operations & ClosureAcid Rock Drainage (ARD)Standard ASTM Humidity Cell

Related Services & Resources

Standard ASTM Humidity Cell

SGS is the global technical leader in the field of humidity cell analysis. We have years of experience helping mining and engineering companies worldwide document the Acid Rock Drainage (ARD) potential of their properties. Our automated laboratories offer complete static and kinetic ARD testing services, with highly trained professionals following fixed testing protocols to ensure reproducible results.

Humidity cell tests are designed to mimic weathering at the laboratory scale in a controlled fashion. The test determines the rate of acid generation, the variation over time in leachate water quality and thus allows you to develop mitigating strategies.

The standard humidity cell test is conducted at the bench scale. The sample is subjected to alternating cycles of dry and moist air to simulate precipitation cycles. The sample is soaked for a specific length of time with deionized water. The water percolates through the sample and is then collected. This leachate is analyzed for a number of parameters including pH, sulfate, acidity, alkalinity, conductivity and metals (including Ca and Mg). The test design can be customized to better account for sample matrix effects by increasing or reducing the particle grain size or altering the shape of the cell and changing the flow rate.

Larger scale cells can test several parameters. The response of coarser samples more typical of waste rock can be assessed.  Various cover design options can be tested and the effectiveness of cover systems in reducing ARD can be assessed. 

Other humidity cell design options that SGS can support include the addition of bacteria, flooding of the sample, temperature cycling, variation of the humid-dry air cycle, and variable duration of the air/leach cycle. Depending on your circumstances, we can design a testing program to truly reflect your operational site.

Humidity cells test results are reviewed monthly to check progress and determine if extended leaching is required. Tests typically run from 16 to 24 weeks. Tests of longer duration are run to evaluate ARD control options. Such tests are designed to provide data for mitigation strategies, thus lessening the effects of ARD. ARD reactions are complex and SGS has the technical expertise to help you with the interpretation of your results.

As the ARD generating and neutralizing minerals leach away, the mineralogy of the leach sample will change. SGS’s high definition mineralogy services provide characterization and documentation of these changes throughout the duration of the test. The integration of our environmental mineralogy expertise gives you a more complete picture of the mineralogical causes of ARD potential and neutralization strategies.

All SGS sampling and laboratory analysis is performed in accordance with recognized global standards such as American Society for Testing and Materials (ASTM) and International Standards Organization (ISO). Partner with us to ensure your ARD testing needs are met by industry experts, allowing you operate in an effective and environmentally responsible manner.

Email Us
Humidity Cell TestingHumidity Cell TestingLaboratory Scale Modeling of Weathering Processes ...

Contact

SGS Headquarters

  • 1 Place des Alpes
  • P.O. Box 2152
  • Geneva, 1211
  • Switzerland
  • t   +41 22 739 91 11
  • f   +41 22 739 98 86
  • e   Email Us

E-SUBSCRIPTIONS

Sign up to SGS publications and newsletters from your region and around the world
STAY UP TO DATE.SUBSCRIBE NOW

Office Directory

Find SGS offices and labs around the world.World map
Office Locator

News

events